Note: product title indicates boiler's Net AHRI (Net IBR) rating
Lancer is a standard-efficiency, cast iron, chimney-vented hot water gas boiler designed to be a high-quality and cost-effective solution for new or replacement boiler installs. It combines traditional, clean design with top-quality controls (concealed behind easy-access front panel) and USA-made, time-tested cast iron heat exchanger - for easy installation, longer life span and uninterrupted performance.
Boiler includes: Integrated Draft Diverter, Automatic Damper (with quick-disconnect harness), HydroStat 3200 control, Honeywell/Resideo Step-Opening Redundant Gas Valve, Taco 007e Circulator Pump w/ Flange Set, Spark Ignition (w/ continuous retry), Resettable Blocked Vent Switch, Drain Valve, Pressure Relief Valve, Temperature & Pressure Gauge and Boiler Manifold.
Cross-References:
- Bosch/Buderus: GC144/3
- Burnham: X-203
- Crown/Velocity: AWR070B
- Dunkirk: DXL-60K, DXL-75, WPSB-3D/DP
- Lennox: GWB84-060E
- New Yorker: CG30F
- Peerless: MI-E-03, MI85-03, MIH II-03, 63-03L
- Pennco: 15B-060K, 15B070FE
- Slant/Fin: S-60-EDP
- Utica: UH15B070FE, UH15B-060K, MGB-060K, MGB-75J
Features:
- Compact & clean design, with integrated rear draft diverter and controls concealed behind front panel
- Premium-level controls: Honeywell/Resideo S8610 & Hydrolevel HydroStat 3200
- Taco 007e high efficiency ECM circulator included (w/ 1-1/4" NPT flanges)
- Honeywell/Resideo gas valve
- Stainless steel precision burners
- Powder coated steel jacket with heavy-gauge, 1" base insulation
- Assembled in Pennsylvania with USA-made components, including robust, time-tested and efficient cast iron heat exchanger with metal section connections for increased boiler life
Technical Specifications:
- Input (BTU): 68,000
- Net AHRI Rating (BTU): 50,000
- DOE Heating Capacity (BTU): 57,000
- Efficiency (AFUE): 84%
- Fuel Type: Natural Gas (can be converted to propane with 110928-01 kit)
- Boiler/System Type: Hot Water (Hydronic) Cast Iron Gas Boiler
- Boiler Connections: 1-1/4" NPT - Supply/Return Connections, 3/4" NPT - Relief Valve, 3/4" NPT - Drain, 1/2" NPT - Gas
- Pressure Specs: 30 psi relief valve setting, 50 psi max. allowed working pressure
- Vent Type: Chimney Vent
- Vent Pipe Size: 4" (standard Cat I galvanized chimney vent pipe)
- Dimensions: 14" Wide x 27" Deep (33-1/4" w/ integrated draft diverter) x 40" High (from floor, without damper installed)
- Weight: 254 lbs
Helpful?
Yes
{{ (2*reviews[i].feedback_helpful) -
reviews[i].feedback_count }}
No
Verified
Purchase
{{ reviews[i].content.title }}
By {{ reviews[i].content.name
}} (from {{
reviews[i].content.location }}) on
{{ reviews[i].created_at | formatDate }}
Ask a Question
{{ f.question }}
Helpful?
Yes
{{ (2*f.feedback_helpful) - f.feedback_count }}
No
By PexUniverse Customer Service on {{ f.answered | formatDate }}