3200-Plus Fuel Smart HydroStat, Temperature Limit, LWCO & Reset Control for Gas Boilers, 120V
Brand: Hydrolevel
Part#: 48-3200
Model: HydroStat 3200-Plus
made in usa
Hydrolevel Fuel Smart 3200-Plus HydroStat is a 120V universal triple-function control for Gas boilers (incl. w/ tankless coil) with fuel-saving boiler reset, temperature limit & low water cut-off capabilities. It is ideally suited for replacing cold-start and triple-action aquastats.
Operates in auto reset mode, but can be switched to manual reset when used with commercial boiler installations.

Cross-References:
  • Honeywell: LA8124E, LA8148E

Features:
  • Universal triple-function control for gas boilers (incl. cold start and w/ tankless coil) - Temperature Limit Control (TLC), Boiler Reset & Low Water Cut-Off (LWCO)
  • Replaces common cold start and triple-action Aquastats (installs on existing well), industry standard wiring
  • Use with Hydrolevel Electro-Well for LWCO functionality
  • Can be set to either Auto (default) or Manual reset mode
  • LWCO test functionality
  • Hinged access cover
  • Dial-type settings inside
  • (6) External colored diagnostic LED's for displaying statuses
  • Dynamic display w/ call for heat indicator
  • Smart DHW priority
  • Thermal Targeting - adjusts boiler temperature based on heating demand
  • Provides automatic shutdown in warm weather w/ optional Outdoor Sensor Kit (sold separately)
  • Optional features include Thermal Pre-Purge for heat conservation, C°/F° display, multiple circulator activation options & enhanced condensing protection
  • Can be mounted to any surface for secure hold and space economy (w/ optional remote mount kit)

Technical Specifications:
  • System Type: Gas-Fired Hot Water Boilers
  • Reset: Automatic or Manual (can be selected)
  • Electro-Well Connection: 3/4" NPT or 1/2" NPT
  • Electrical Specs: 120V (Input Voltage), 60 Hz, SPDT (Relay Type), NEMA 1 Enclosure
  • Control Contacts: 30VA @ 24 VAC (Burner); 5.8 FLA, 34.8 LRA @ 120VAC (Circulator)
  • Temperature Range: Low Limit - Off for 110°F - 200°F, High Limit - 100°F - 220°F, Differential - Auto (varies between 10°F and 20°F subtractive based on setting and boiler temperature)
Write a Review
Helpful? Yes {{ (2*reviews[i].feedback_helpful) - reviews[i].feedback_count }} No
Verified Purchase
{{ reviews[i].content.title }}
Reply from PexUniverse:
By {{ reviews[i].content.name }} (from {{ reviews[i].content.location }}) on {{ reviews[i].created_at | formatDate }}
Ask a Question
{{ f.question }}
Helpful? Yes {{ (2*f.feedback_helpful) - f.feedback_count }} No
By PexUniverse Customer Service on {{ f.answered | formatDate }}

Recently viewed products

Top